Skip to content
Welcome to fluid-hub, the B2B hydraulics shop.
ATOS

Images are for illustrative purposes only. Please refer to the data sheet for exact specifications.

ATOS

AGIRR-20/210/V ** Pressure Reducing Valve with Check Valve NG20

Code AGIRR-20/210/V 51|AGIRR-20/210/V **|Pressure Control On-off Valves

With the check valve built into the main body, AGIRR-20/210/V ** by Atos provides pressure reduction and anti-back-flow in a single component. NG20 plate, 350 bar, 300 l/min, 7÷210 bar.


Technical specifications:

  • Maximum pressure: 350 bar (ports A, B, X); port Y: 0 bar
  • Maximum flow rate: 300 l/min
  • Pressure setting range: 7÷210 bar
  • Mounting interface: NG20 – Mounting surface ISO 5781-08-10-0-00
  • Port sizes A, B: G 1"; ports X, Y: G 1/4"
  • Seals: NBR – Fluid temperature: -20°C to +80°C
  • Compatible fluids: Mineral oils
  • Recommended viscosity: 15 to 100 mm²/s
  • Maximum fluid contamination level: ISO 4406 class 20/18/15
  • Pressure adjustment via threaded screw with cap (clockwise rotation = pressure increase)
  • Handwheel adjustment instead of screw with cap (option /V)
  • Integrated check valve in the main body: prevents back-flow towards the reduced line
  • Weight: 5.7 kg
  • MTTFd: 75 years (EN ISO 13849)
  • CE compliance – Low Voltage Directive 2014/35/EU, RoHS, REACH
  • Corrosion resistance: salt spray test (EN ISO 9227) > 200 h

Typical applications:

  • sheet metal stamping and blanking machines
  • hydraulic power units with multiple pressure circuits
  • assembly and production line systems

TECHNICAL DETAILS

Features and data sheet

ManufacturerATOS
SeriesAGIRR
TypePILOT OPERATED PRESSURE REDUCING VALVE
Pressure range (bar)7 ÷ 210
Maximum pressure (bar)350
Maximum flow rate (l/min)300
Seal materialsNBR
Mounting interfaceNG20
Technical notesCON VALVOLA DI RITEGNO
View data sheet

Reserved price*

Log in or register to see details

LOG IN OR REGISTER
o
REQUEST SPECIAL CONDITIONS

Related categories