AGIRR-10/210 ** Pressure Reducing Valve with Check Valve NG10

Code AGIRR-10/210 51|AGIRR-10/210 **|Pressure Control On-off Valves

With the check valve built into the main body, AGIRR-10/210 ** by Atos provides pressure reduction and anti-back-flow in a single component. NG10 plate, 350 bar, 160 l/min, 7÷210 bar.


Technical specifications:

  • Maximum pressure: 350 bar (ports A, B, X); port Y: 0 bar
  • Maximum flow rate: 160 l/min
  • Pressure setting range: 7÷210 bar
  • Mounting interface: NG10 – Mounting surface ISO 5781-06-07-0-00
  • Port sizes A, B: G 1/2"; ports X, Y: G 1/4"
  • Seals: NBR – Fluid temperature: -20°C to +80°C
  • Compatible fluids: Mineral oils
  • Recommended viscosity: 15 to 100 mm²/s
  • Maximum fluid contamination level: ISO 4406 class 20/18/15
  • Pressure adjustment via threaded screw with cap (clockwise rotation = pressure increase)
  • Integrated check valve in the main body: prevents back-flow towards the reduced line
  • Weight: 3.5 kg
  • MTTFd: 75 years (EN ISO 13849)
  • CE compliance – Low Voltage Directive 2014/35/EU, RoHS, REACH
  • Corrosion resistance: salt spray test (EN ISO 9227) > 200 h

Typical applications:

  • sheet metal stamping and blanking machines
  • hydraulic power units with multiple pressure circuits
  • assembly and production line systems

TECHNICAL DETAILS

Features and data sheet

ManufacturerATOS
SeriesAGIRR
TypePILOT OPERATED PRESSURE REDUCING VALVE
Pressure range (bar)7 ÷ 210
Maximum pressure (bar)350
Maximum flow rate (l/min)160
Seal materialsNBR
Mounting interfaceNG10
Technical notesCON VALVOLA DI RITEGNO