Images are for illustrative purposes only. Please refer to the data sheet for exact specifications.
ATOS
AGIR-10/350/V ** /PE Pressure Reducing Valve NG10
Designed for demanding operating environments, the pilot-operated reducing valve AGIR-10/350/V ** /PE by Atos ensures accurate downstream pressure maintenance. NG10 subplate, 350 bar max, up to 160 l/min, setting range 8÷350 bar.
Technical specifications:
- Maximum pressure: 350 bar (ports A, B, X); port Y: 0 bar
- Maximum flow rate: 160 l/min
- Pressure setting range: 8÷350 bar
- Mounting interface: NG10 – Mounting surface ISO 5781-06-07-0-00
- Port sizes A, B: G 1/2"; ports X, Y: G 1/4"
- Seals: FKM – Fluid temperature: -20°C to +80°C
- Compatible fluids: Mineral oils, fire-resistant fluids without water
- Recommended viscosity: 15 to 100 mm²/s
- Maximum fluid contamination level: ISO 4406 class 20/18/15
- Pressure adjustment via threaded screw with cap (clockwise rotation = pressure increase)
- Handwheel adjustment instead of screw with cap (option /V)
- Weight: 3.3 kg
- MTTFd: 75 years (EN ISO 13849)
- CE compliance – Low Voltage Directive 2014/35/EU, RoHS, REACH
- Corrosion resistance: salt spray test (EN ISO 9227) > 200 h
Typical applications:
- construction machinery: hydraulic cranes, drilling rigs, mixers
- special vehicles and off-road equipment with multi-zone circuits
- test benches and hydraulic test rigs
TECHNICAL DETAILS
Features and data sheet
| Manufacturer | ATOS |
| Series | AGIR |
| Type | PILOT OPERATED PRESSURE REDUCING VALVE |
| Pressure range (bar) | 8 ÷ 350 |
| Maximum pressure (bar) | 350 |
| Maximum flow rate (l/min) | 160 |
| Seal materials | FKM |
| Mounting interface | NG10 |